Feature | Specification |
Measurement Range | 10-600 mg/d L (0.6 -33.3 mmol/L) |
Testing Method | Electrochemical Biosenor |
Coding | Auto-coding |
Test Time | 5 seconds |
Sample Volume | 0.5μL |
Sample Type | Fresh Whole Blood(capillary) |
Operation Temperature Range | 5-45°C |
Hematocrit Range | 20-70% |
Strip Shelf-life (unopened) | 24 months |
Strip Shelf-life (opened) | 6 months |
Strip Storage Temperature | 2-30°C |
Humidity Exposure Limit for Strip | 10-90%R.H. |
Feature | Specification |
Measurement Range | 10-600 mg/dL (0.6 -33.3 mmol/L) |
Testing Method | Electrochemical Biosenor |
Coding | Auto-coding |
Test Time | 5 seconds |
Sample Volume | 0.5uL |
Sample Type | Fresh Whole Blood(capillary,venous, arterial, neonatal) |
Operation Temperature Range | 5-45°C |
Hematocrit Range | 0-70% |
Strip Shelf-life (unopened) | 24 months |
Strip Shelf-life (opened) | 6 months |
Strip Storage Temperature | 2-30°C |
Humidity Exposure Limit for Strip | 10-90%R.H. |
Feature | Specification |
Measurement range | 10-600 mg/dL(0.6-33.3 mmol/L) |
Testing Method | Electrochemical Biosenor |
coding | Auto-coding |
Test Time | 5 seconds |
Sample Volume | 0.5μL |
Sample Type | Fresh whole blood (capillary) |
Operation Temperature Range | 5-45°C |
Hematocrit Range | 0-70% |
Strip shelf-life (unopened) | 24 months |
Strip shelf-life (opened) | 6 months |
Strip storage Temperature | 2-30°C |
Humidity Exposure Limit for Strip | 10-90%R.H. |
Feature | Specification |
Measurement range | 10-600 mg/dL |
Result calibration | Plasma-equivalent |
Sample | Fresh capillary whole blood |
Enzyme | Glucose dehydrogenase |
Sample size | About 0.5 μL |
Testing time | 5 seconds |
Operation temperature | 5 - 45°C (41 - 113°F) |
Operation humidity | 10 - 90% (non-condensing) |
Feature | Specification |
Measurement Range | 0.1-8.0 mmol/L |
Testing Method | Electrochemical Biosenor |
Coding | Auto-coding |
Test Time | 10 seconds |
Sample Volume | 0.8μL |
Sample Type | Fresh Whole Blood(capillary) |
Operation Temperature Range | 7.5 - 45°C |
Hematocrit Range | 20 - 65% |
Strip Shelf-life (unopened) | 24 months |
Strip Shelf-life (opened) | 6 months |
Strip Storage Temperature | 2 - 30°C |
Humidity Exposure Limit for Strip | 10 - 90%R.H. |
Feature | Specification |
Measurement Range | 2.86-20 mg/dL(170-1190umol/L) |
Testing Method | Electrochemical Biosenor |
Coding | Auto-coding |
Test Time | 6 seconds |
Sample Volume | 1.5uL |
Sample Type | Fresh Whole Blood(capillary, venous) |
Operation Temperature Range | 10-40°C |
Hematocrit Range | 10-70% |
Strip Shelf-life (unopened) | 24months |
Strip Shelf-life (opened) | 6 months |
Strip Storage Temperature | 2-30°C |
Humidity Exposure Limit for Strip | 10 - 90%R.H. |
Feature | Specification |
Measurement Range | 0.5 -25.0 mmol/L |
Testing Method | Electrochemical Biosenor |
Coding | Code Strip |
Test Time | 10 seconds |
Sample Volume | 0.5μL |
Sample Type | Fresh Whole Blood(capillary) |
Operation Temperature Range | 10 - 45°C |
Hematocrit Range | 20 - 70% |
Strip Shelf-life (unopened) | 24 months |
Strip Shelf-life (opened) | 6 months |
Strip Storage Temperature | 2 - 30°C |
Humidity Exposure Limit for Strip | 10 - 90%R.H. |